Mylex eXtremeRAID Guía de instalación Pagina 79

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 210
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 78
Configuration
Manual No. 771961 4-29
Expert Controller Options (All External RAID Controllers)
Click the Expert button in the Advanced Controller Options dialog box to
inspect and/or change expert-level External RAID Controller Options. These
options should remain at their defaults unless you have a high degree of
expertise with External RAID Controller Options.
Figure 4-26. Expert Controller Options Dialog Box
In the Expert Controller Options dialog box (Figure 4-26), you have the
option to do any of the following:
Enable (by checking) or disable (by unchecking) any of the following
options:
Simplex No RSTCOM. Allows a controller not to assert a reset
signal to its partner controller. Simplex environments only.
Left Symmetric RAID5 Algorithm. Changes a Right Symmetric
RAID 5 parity scheme to Left Symmetric. This item is available
only when there are no logical drives defined.
On Q Full Give Busy. When a command is received and the
controller detects a full queue, it will return a busy status rather
than Queue Full. This helps hosts that do not accurately deal with
Vista de pagina 78