Mylex eXtremeRAID Guía de instalación Pagina 77

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 210
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 76
Configuration
Manual No. 771961 4-27
Advanced Controller Options (All External RAID Controllers)
Click the Advanced button in the Controller Options dialog box to inspect
and/or change additional External RAID Controller Options.
Figure 4-25. Advanced Controller Options Dialog Box
In the Advanced Controller Options dialog box (Figure 4-25), you have the
option to do any of the following:
Set the following limits:
Queue Limit. Maximum allowed queue depth for tagged commands
to each attached drive. Settings are from 1 (no tags) to 230.
MAXIOPs Limit. Sets maximum number of IOP structures allowed
for controller command operations, limiting the number of
simultaneous commands. Settings are from 64 to 244.
Enable (by checking) or disable (by unchecking) any of the following
options:
Conservative Cache Mode. Turns off write cache while a failover
condition persists, allowing an extra degree of data safety.
SAF-TE Use of UPS. Enables monitoring of uninterruptable power
supply if it is also supported by the system enclosure.
Restrict Reassign to One Block. Restricts a reassign to the failing
block. If disabled, reassigns will be for the entire current I/O blocks,
Vista de pagina 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 209 210

Comentarios a estos manuales

Sin comentarios